توضیحات
ماژول PWM ژنراتور XY-LPWM:
Instruction
1, set the frequency of the PWM
“F101”: Set the frequency to 101 HZ (001~999)
“F1.05”: Set the frequency to 1.05 KHZ (1.00~9.99)
“ F10.5 ”: Set the frequency to 10.5KHZ (10.0~99.9)
“F1.0.5”: Set the frequency to 105KHZ (1.0.0~1.5.0)
2, set the duty cycle of the PWM
“DXXX”: Set the duty cycle of PWM to XXX ; (001~100)
For example, D050 , set the PWM duty cycle to be 50%.
3, read the setting parameters
Send a ” read ” string and read the set parameters.
Set the success to return: DOWN ;
Setting failed to return: FALL .